PAC900S12-B2

I-AC ukuya kwi-DC Ubonelelo lwaMandla lweModyuli ye-HVDC-DC

I-PAC900S12-B2 isekela igalelo le-AC le-90 V ukuya kwi-264 V kunye ne-HVDC igalelo le-180 V ukuya kwi-300V.
I-PSU ibonelela ngemveliso enye kwaye ixhasa iindlela ezintathu zokukhupha i-MV12, i-SV12 kunye ne-MV6.


Linkedin
43f45020
384b0cad
754c4db4
6ec95a4a

Iinkcukacha zeMveliso

Iithegi zeMveliso

Amandla emveliso alinganisiweyo yi-900 W. I-PSU iyatshintshatshintsha, ilingana ngoku, kwaye ixhasa i-1 + 1 okanye i-2 + 2 uxhulumaniso oluhambelanayo.
I-PSU ixhasa unxibelelwano lwe-PMBus, kwaye ithumela ulwazi lwe-PSU kwisistim ukuququzelela ukubeka iliso nokulawula.

Iimbonakalo
● fficc 94% (Vin = 230 V AC, Pout = 450 W, TA =25 ° C, ngaphandle kwefeni)
● Ubunzulu x Ububanzi x Ubude: 183.0 mm x 68.0 mm x40.5 mm
● Igridi yamandla: 110 V AC/220 V AC isigaba esisodwa, 240 VDC
● Ixhasa ukhuseleko lwegalelo le-AC lokungabikho kwamandla ombane, ukugqithiswa kwamandla,
i-overcurrent, isiphaluka esifutshane, kunye ne-PFC overvoltage
● Ixhasa ukukhuselwa kwegalelo le-HVDC ku-overvoltage, undervoltage, kunye ne-PFC overvoltage
● Ixhasa ukhuseleko lwemveliso yombane ogqithisileyo, i-overcurrent, i-short circuit, kunye ne-overtemperature
● I2C yolawulo, inkqubo, kunye nokubeka iliso
● I-CE, UL, TUV, CCC, BSMI, BIS cfic kunye ne-CB ingxelo ekhoyo
● 80 Plus platinum amandla fficc cfic
● IEC 60950-1, EN 60950-1, UL 60950-1, GB 4943.1, IEC 62368-1
● I-RoHS iyahambelana
Usetyenziso: Iseva
I-PSU inokumelana ne-voltage yegalelo ye-318 V AC kwiiyure ze-48 (ilizwe elingasebenziyo liyamkeleka).
I-inrush yangoku kufuneka ihlangabezane neemfuno kwi-ETSI EN 300 132-3.
Xa uvavanya ubuninzi begalelo langoku, qinisekisa ukuba i-voltage ye-port input port ihlangabezana nemfuneko kwaye imveliso yi-900 W.
IiMfuno zoYilo lwangoku lweSabelo
1. Ixhasa i-1 + 1 okanye i-2 + 2 imodi. Ukwabelana ngoku kuphela kwimo ye-MV12.
2. Umthwalo opheleleyo ekuqalisweni kweemeko zokusebenza ngokuhambelanayo kufuneka ube ngaphantsi komthwalo olinganisiweyo we-PSU enye.
3. Xa i-PSU isebenza kwimodi ye-1 + 1 okanye i-2 + 2, ukuba enye yee-PSU isebenza kwimodi ye-MV6 kunye nezinye ii-PSU zisebenza kwimodi ye-MV12, ii-PSU kufuneka zisebenze ngokufanelekileyo ngaphandle kwe-ffc enye kwenye.
4. Kwiimeko apho i-ff PSUs ingafakwanga kunye, izibonakaliso ze-I-MON zee-PSU ezimbini akufanele zikhuphe ukusebenza okuqhelekileyo kwee-PSU xa zidibaniswe ngokuthe ngqo.
5. Ukungalingani kwangoku ukwabelana kuphela kwimeko yobushushu obuqhelekileyo.








  • Ngaphambili:
  • Okulandelayo: